Select your language

Dermatology

The entry level in high frequency ultrasound imaging systems.

with 22 MHz applicator

Key features

  • Max. axial resolution: 57 µm at 28 MHz
  • Max. digitizing depth: 8 mm
  • Scan width: 12.8 mm linear (33 µm step width)
  • Medical CE and FDA 510K
  • Connection: USB 2.0 or USB 3.0
  • DUB SkinScanner software compatible with all Windows operating systems
  • Viewing modes: B-Scan, A-Scan, Sum-A,
    ScanLoop (20)
  • 2 color scales
  • Measurement: length, area, density, width, depth
  • Automatic skin thickness and skin density
  • Personalizable: e.g. clinic or doctor‘s name

The standard system in high frequency ultrasound imaging systems.

for 22 or 33 MHz applicators

Key features

  • Max. axial resolution: 42 µm at 38 MHz
  • Max. digitizing depth: 16 mm
  • Scan width: 12.8 mm linear (33 µm step width)
  • Medical CE and FDA 510K
  • Connection: USB 2.0 or USB 3.0
  • DUB SkinScanner software compatible with
    all Windows operating systems
  • Viewing modes: B-Scan, RF-Mode, A-Scan,
    Sum-A, 
    ScanLoop (2000)
  • Filter: Hilbert transformation
  • 7 color scales
  • Measurement: length, area, density, width,
    depth, ROI, rectangular measuring field
  • Automatic skin thickness
  • Automatic skin density
  • Personalizable: e.g. clinic or doctor‘s name

Available applicators

  • Linear B-Scan 22-28 MHz
    Max. penetration/axial resolution: 10 mm / 57 µm
  • Linear B-Scan 33-38 MHz
    Max. penetration/axial resolution: 6 mm / 42 µm

High frequencies with one ultrasound imaging system.

for 18, 22, 33, 50 or 75 MHz applicators

Key features

  • Max. axial resolution: 21 µm at 75 MHz
  • Max. digitizing depth: 16 mm
  • Scan width: 12.8 mm linear (33 µm step width)
  • Medical CE and FDA 510K
  • Connection: USB 2.0 or USB 3.0
  • DUB SkinScanner software compatible
    with all Windows operating systems
  • Viewing modes: B-Scan, RF-Mode, A-Scan,
    Sum-A, 
    ScanLoop (2000)
  • Filter: Hilbert transformation
  • 7 color scales
  • Measurement: length, area, density, width,
    depth, ROI, rectangular measuring field
  • Automatic skin thickness
  • Automatic epidermis thickness (50 and 75 MHz)
  • Automatic skin density
  • Personalizable: e.g. clinic or doctor‘s name

Available applicators

  • Linear B-Scan 18-22 MHz
    Max. penetration/axial resolution: 15 mm / 72 µm
  • Linear B-Scan 22-28 MHz
    Max. penetration/axial resolution: 10 mm / 57 µm
  • Linear B-Scan 33-38 MHz
    Max. penetration/axial resolution: 6 mm / 42 µm
  • Linear B-Scan 50 MHz
    Max. penetration/axial resolution: 4 mm / 31 µm
  • Linear B-Scan 75 MHz
    Max. penetration/axial resolution: 3 mm / 21 µm